Junk Plant Watts Bar 2: New Plant Scram On Unreliable Equipment.


Power ReactorEvent Number: 52194
Facility: WATTS BAR
Region: 2 State: TN
Unit: [ ] [2] [ ]
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DAVID ALLEN
HQ OPS Officer: JEFF HERRERA
Notification Date: 08/23/2016
Notification Time: 15:30 [ET]
Event Date: 08/23/2016
Event Time: 13:56 [EDT]
Last Update Date: 08/23/2016
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
ERIC MICHEL (R2DO)

UnitSCRAM CodeRX CRITInitial PWRInitial RX ModeCurrent PWRCurrent RX Mode
2M/RY43Power Operation0Hot Standby
Event Text
MANUAL TRIP DUE TO A LOSS OF MAIN FEEDWATER

"On August 23, 2016, at 1356 EDT, Watts Bar Nuclear Plant [WBN] Unit 2 reactor was manually tripped due to a loss of main feedwater.

"Concurrent with the reactor trip, the Auxiliary Feedwater system actuated as designed.

"All control and shutdown rods fully inserted. All safety systems responded as designed. The unit is currently stable in Mode 3, with decay heat removal via Auxiliary Feedwater and main steam dump systems. Unit 2 is in a normal shutdown electrical alignment.

"The cause is currently under investigation.

"This is being reported under 10CFR 50.72(b)(3)(iv)(A) and 10CFR 50.72(b)(2)(iv)(B).

"There was no effect on WBN Unit 1.

"The NRC Senior Resident Inspector has been notified."