Showing posts with label Nuclear Power. Show all posts
Showing posts with label Nuclear Power. Show all posts

Thursday, August 25, 2011

VY Turbine Lube Oil Vapor Extractor Plume

 Updated 6/30
Fukushima accident: March 11, 2011
The Vermont Yankee state liaison engineer documenting my concern....
 
I find it highly suspicious they can’t come up with a preliminary or back of a napkin estimation of the flow and the radioactive content in the plume.  
New Oct 18, 2011

The Vermont state nuclear engineer Uldis Vanags updated me on the results of my 2.206 and his investigation of the VY turbine lube oil vapor extractor fan radioactive release today. On Sept 12 Entergy wrote up a condition report CR-VTY-2011-03628 acknowledging they didn't ever have a analysis or technical evaluation of this release pathway with the vapor extractor discharge...never measured radiation...I wrote my 2.206 on Aug 26, 2011.

There is an expectation this pathway released radiation unmonitored...it is openly controversial now if their environmental reports ever were completely accurate.  Now it is a nationwide concern at BWRs if their radiological environmental reports were ever accurate if they had a LO vapor extractor...
 
It doesn't get passed any of us with the NRC answering me on Oct 4 "because the petition failed to provide sufficient facts to warrant further inquiy", while on Sept 12 Entergy wrote up CR-VTY-2011-036328 completely validating a response to my concern. Entergy has contracted with Areva nuclear to preform a investigation over this and measure vapor extractor radioactivity and evaluate if it reportable and radioactive environmental reports are accurate.

New Oct 17, 2011

Mr Kim,
For the PRB's interest, I got the Vermont nuclear engineer going into VY this week asking Entergy questions about the turb building plume and the vapor extractor.
mike

New Oct 12, 2011
Oh, I get it now, if Entergy and NRC don't have to disclose the facts, then there is never enough evidence for a 2.206 to be accepted.

Like I always have said, transparency is a enabler to meaningful public participation...

Mr. Mulligan,
On October 4, 2011, the PRB met internally to discuss the petition and to make the initial recommendation. The PRB determined that some of the petition requests do not meet the criteria for review because the petition failed to provide sufficient facts to warrant further inquiry. The remaining requests within the petition meet the criteria for rejection because they have already been reviewed, evaluated, and resolved by the NRC during prior 10 CFR 2.206 reviews. Therefore, the PRB’s initial recommendation is to not accept your petition.
Thanks

James Kim
Project Manager, DORL
U.S. Nuclear Regulatory Commission
301-415-4125

Yankee hearing leaves unanswered questions
David McElwee, an Entergy engineer, told the legislative panel Tuesday that it was a result of rain washing off radiation from a roof on the turbine building, and getting into the storm drain. The ventilation problem was discovered in 1993, but there was no explanation about why the Cobalt 60 wasn't discovered until 1997."
By Susan Smallheer STAFF WRITER - Published: September 17, 2009

BRATTLEBORO – Entergy Nuclear refused to say Wednesday how Cobalt 60, a radioactive byproduct of the nuclear fission process, ended up in the Connecticut River in 1997, an issue that surfaced earlier this week during a legislative hearing on radiation monitoring at the Vermont Yankee plant.

Robert Williams said Entergy was preparing a report on the issue for the Committee on Administrative Rules and said it would decline further comment.

Williams said Cobalt 60 had gotten into the storm drains at Vermont Yankee and had ended up in the Connecticut River as a result of a ventilation problem, but he declined to say how the Cobalt 60 got out of the plant itself.
I bet you I am the first one in the history of Vermont Yankee who ever captured in a picture a steam or vapor plume emanating from the turbine or reactor building. My photograph of the any vapor plume was the first...

You can click on the Picasa link on the title...it is about 1.25 miles from my camera. You can keep clicking on the picture until it gets big enough for you.

The vapor extractor takes a suction on all the main turbine lube oil bearings. It looks like to me it sucks in main steam line reactor vessel steam. I think it provides a function like the main condenser where non condensables and other radionuclide congregate, basically increase concentration, then they go off for filtering and processing in the AOG system. I contend they are discharging reactor steam and vapor without radiological monitoring and the typical filtering that goes in AOG. It is bypassing the AOG. They got a grossly inaccurate radiological environmental report.

Remember, on a yearly bases this is huge amount of water....this goes on day in and day out.

There are many other BWR plants with the same setup. I think it is a national scandal with environmental reporting.

The plume (small) is behind the tall reactor rebuilding. It is on the roof of the shorter green turbine building, to the right of the reactor building.

Today the plume is heading directly towards Brattleboro Vermont...